indexing Coolant Filter

The Easyband series of indexing coolant filters offer the simplest and most versatile solution for the filtration of machine tool
coolants. The Easyband Coolant Filter is the result of careful and thorough research that combines the reliable traditional elements and characteristics of a fabric gravity bed filter with an innovative construction and new design concepts.

The Easyband indexing Coolant Filter is designed for use on all different types of metalworking machine tools and can filter emulsions/water based and whole oils coolants up to a maximum viscosity of 20° cSt at 100°F (40°C). Filtration capacity is for flow ranges from 13.2 - 105.6 gpm (50 to 500 lt/min).

Depending on the fabric used, the filtration efficiency ranges from 10 to 60 microns.

What makes the Easyband Coolant Filter Different?

The solid and robust construction of this coolant filter consists of the following benefits;

The filtering unit consists of two recessed, perforated trays, made of sturdy galvanized metal (stainless steel on request), all components are shaped by an automatic bending machine without welding, .

The frame supports the shafts with pinions and pulleys that hold the net and moves the conveyor belt.

The indexing conveyor is operated by a gear reduction motor that is controlled by a float and starting micro switch.

The coolant tank serves as the roll-holder while providing shaft protection and also contains the coolant re-circulation pump.

The Easyband Coolant Filter is finished with a high quality powder coated finish for a long life. The coolant filter comes completed with an electric control panel, coolant tank, filter bed, re-circulation pump and waste bin.A variety of optional accessories are available to customize the unit to your unique needs.

If a higher level of filtration is required, please see our Evotech deep bed coolant filter.

IMPROVE YOUR CUTTING TOOL LIFE AND YOUR FINISH QUALITY BY FILTERING YOUR COOLANT

 

How It Works;

The contaminated liquid is sent into a trough (2) that distributes it uniformly on the filter media (1) below. As the solids are removed and progressively accumulate on the filter media, the sludge restricts the flow through the media. As the liquid level rises on the filter media the float switch begins to rise and eventually triggers the micro switch indexing the filter. This switch starts the gear reduction motor and pulls the used fabric forward into a waste collection tank (3). The filtered coolant passes into the coolant tank (4) and subsequently, depending on the application and accessories, can be re-circulated back into the
machine tool with the on board electric pump (5).

 

Easyband Coolant Filter, How it works

TECHNICAL DETAILS

MODEL

TANK CAPACITY

Gallons (Liters)

FLOW CAPACITY

Water based

FLOW CAPACITY

Oil

MOTOR SIZE
Pump

HP (kw)

MOTOR SIZE
Gear Motor

HP (kw)

Easyband 50
50 (185)
13.2 (50)
6.6 (25)
0.21 (0.16)
0.16 (012)
Easyband 100
85 (320)
26.4 (100)
13.2 (50)
0.40 (0.30)
0.16 (012)
Easyband 150
135 (510)
39.6 (150)
19.8 (75)
0.53 (0.40)
0.16 (012)
Easyband 200
168 (635)
52.8 (200)
26.4 (100)
0.71 (0.53)
0.16 (012)
Easyband 250
204 (770)
66 (250)
33 (125)
1.0 (0.78)
0.16 (012)
Easyband 300
240 (910)
79.2 (300)
39.6 (150)
1.54 (1.15)
0.16 (012)
Easyband 400
313 (1185)
105.6 (400)
52.8 (200)
1.97 (1.47)
0.16 (012)
   
Easyband with Kalamit
Optional KALAMIT magnetic separator (1) fits right on the top to remove ferrous metal for enhanced scrap salvage or to extend the life of the indexing filter media.
 

Get PDF

Contact: info@micronfilterusa.com

Home Products Mist Collectors Microil KUBE Quad Elektra EcoTech Dry Dust Collectors Airjet Mini-Airjet Sharp Coolant Filters Easyband EvoTech Kalamit Maxflow Oil Clean Spin Custom Systems Bench Top Extractors Coolant Chller Downloads About Us Anouncements Contact Coolant filters  Custom coolant filters  Dust Collectors  Mist Collectors  Filter Finder